Question : ESP Design affected by Gas

Post by KUH »

Dear Fanarco Members,
Please help me : how to design ESP if any high GOR in surface.

Thanks...
User avatar
FANARCO
Administrator
Administrator
Posts: 2068
Joined: Mon Jul 10, 2006 9:56 pm
Contact:

Post by FANARCO »

I think more that 4000 SCF/STB GOR it is not allowed to use ESP
Try another artificial lift like gas lift or Jet pump...... etc depends on your conditions
KUH
Posts: 2
Joined: Fri May 09, 2008 12:18 am

Post by KUH »

In our field GOR still between 100 - 400 scf/stb.

I change my question : how to calculate Intake Pressure/ Pwf/ Ps if any GOR in surface. Available data : BFPD, BOPD, WFL (working fluid level) and SFL (Static Fluid level), SG oil, water & gas.
IF No GOR, I was used to apply below formulas :
SG Composite = SG water * WC + SG oil * (1-WC)
Intake Pressure = (Pump Setting Depth - WFL) * 0.433 * SG Composite
etc.
ETMANCO
Posts: 2
Joined: Wed Jun 04, 2008 8:39 pm

Best reply

Post by ETMANCO »

Dear Member;
there are Four basic metods used to avoid or control high GOR
1-Gas Separation
2-Gas Handling
3-Gas avoidance
4-VSD

so please find the attached file which shows all you need

Eng.Abdel Fattah
You do not have the required permissions to view the files attached to this post.
a7madstyle
Junior member
Posts: 69
Joined: Mon Feb 05, 2007 4:42 am

Post by a7madstyle »

Dear ETMANCO

Could u download this pdf file on 4shared or fanarco upload center please !
zlith
Junior member
Posts: 55
Joined: Tue Jun 17, 2008 7:30 pm

Post by zlith »

thanks for sharing!!!