Postby FANARCO » Tue Dec 19, 2017 5:44 pm

muhanad1992 wrote:i did it

You sent a screenshot from PLT RIH not build up
User avatar
FANARCO
Administrator
Administrator
 
Posts: 1992
Joined: Mon Jul 10, 2006 9:56 pm

Re: Help in saphir interpretation

Postby muhanad1992 » Wed Dec 20, 2017 3:39 pm

i will send sequence of events for the job
muhanad1992
 
Posts: 32
Joined: Sun Oct 23, 2016 2:22 pm

Re: Help in saphir interpretation

Postby FANARCO » Wed Dec 20, 2017 4:11 pm

muhanad1992 wrote:i will send sequence of events for the job


I went through the events in details.

After shut in the well for build up they performed shut in pass by Memory PLT which affecting the downhole pressure readings.
Just to conform either the memory gauges in hole and hanged on RZB pump hanger or not.
User avatar
FANARCO
Administrator
Administrator
 
Posts: 1992
Joined: Mon Jul 10, 2006 9:56 pm

Re: Help in saphir interpretation

Postby muhanad1992 » Thu Dec 21, 2017 4:28 pm

in fact this is the first time heard about RZB pump hanger ^_^ we don't use it here in our field, can you please give me simple information about it
muhanad1992
 
Posts: 32
Joined: Sun Oct 23, 2016 2:22 pm

Re: Help in saphir interpretation

Postby FANARCO » Mon Dec 25, 2017 4:17 pm

muhanad1992 wrote:in fact this is the first time heard about RZB pump hanger ^_^ we don't use it here in our field, can you please give me simple information about it

I mean did u put the memory gauges in hole while PLT job and where
User avatar
FANARCO
Administrator
Administrator
 
Posts: 1992
Joined: Mon Jul 10, 2006 9:56 pm

Re: Help in saphir interpretation

Postby muhanad1992 » Tue Dec 26, 2017 2:29 pm

no only PLT parked at 10 m above Top perforation, and when we took passes there is no reading for pressure.

my friend i have another question for you ^_^

what is the effect if i park the tool 100 m above top perforation instead of 10 m in under saturation reservoirs ??
muhanad1992
 
Posts: 32
Joined: Sun Oct 23, 2016 2:22 pm

Re: Help in saphir interpretation

Postby FANARCO » Thu Jan 04, 2018 6:01 pm

The elevation is not too much so, i cannot find a significant change in saturation pressure