Search found 12 matches
- Wed Feb 01, 2012 7:53 am
- Forum: Conventional Reservoir Engineering
- Topic: Condensate reservoir
- Replies: 5
- Views: 2156
In Gas Condensate reservoir the surface recombined sample should be more accurate I would agree on that only if you dont have a representative bottom hole sample. If you have uncontaminated MDT sample or if you have bottom hole sample which was collected at higher pressure than dew point why should...
- Tue Jan 31, 2012 5:55 am
- Forum: Conventional Reservoir Engineering
- Topic: Condensate reservoir
- Replies: 5
- Views: 2156
sorry I couldnt understand one point. if you have mdt samples and surface samples, which one would be more accurate?(assuming both were taken in ideal conditions) here are three sources for PVT sampling; You can get it from MDT or Downhole sampling using WireLine/E Line or Surface recombined sample....
- Mon Jan 09, 2012 2:36 am
- Forum: Conventional Reservoir Engineering
- Topic: Deep Tight Gas
- Replies: 2
- Views: 1182
from my experience they tend to be naturally fractured. from simulation point of view, compressibility factors are quite low and therefore most of the driving mechanism is rock compresiblity. operationally fracturing operations are very difficult, acid stimulation sometimes works. but you would need...
- Sun Jan 08, 2012 11:53 pm
- Forum: Surface Facilities
- Topic: ebook Production Facilities SPE 25
- Replies: 3
- Views: 3294
- Sun Jan 08, 2012 11:45 pm
- Forum: Conventional Reservoir Engineering
- Topic: Oil FVF
- Replies: 3
- Views: 1553
- Thu Jan 05, 2012 4:23 am
- Forum: Oil Well Drilling Engineering
- Topic: why we use liner ??
- Replies: 5
- Views: 3671
- Thu Jan 05, 2012 4:21 am
- Forum: Conventional Reservoir Engineering
- Topic: Pwf from surface Conditions
- Replies: 4
- Views: 1890
- Thu Jan 05, 2012 4:15 am
- Forum: Pipeline Technology
- Topic: Transportation by shuttle tankers
- Replies: 4
- Views: 5186
- Sat Dec 31, 2011 5:17 am
- Forum: Conventional Reservoir Engineering
- Topic: Research on three phase relative permeability
- Replies: 8
- Views: 3226
- Fri Oct 28, 2011 11:35 pm
- Forum: Conventional Reservoir Engineering
- Topic: How to identify the fluid type in the reservoir
- Replies: 2
- Views: 1611
Hi Fanarco Can you share more information about recombination. what is the GOR or CGR assumed for recombination,also the density of samples? From my experience if you have sampled gas on both samplings it should be gas reservoir. Condensate drop out occurs either at reservoir, bottom hole or at sepa...
- Fri Oct 28, 2011 4:46 am
- Forum: Conventional Reservoir Engineering
- Topic: Lectures of SUBJECT (Well Testing)
- Replies: 20
- Views: 16760
- Thu Oct 27, 2011 3:13 am
- Forum: Conventional Reservoir Engineering
- Topic: Help Needed
- Replies: 1
- Views: 1006
Help Needed
Dear Brothers
Can anyone share the k*a*p*p*a p*t*a and p*e*t*e*x I*P*M suite softwares?
thanks in advance
Can anyone share the k*a*p*p*a p*t*a and p*e*t*e*x I*P*M suite softwares?
thanks in advance